Activity Level Indicator Installation Instructions

How to install the Microshare Activity Level Indicator (Motion Based) solution


Activity Level Indicator Solution Installation Guide

This guide includes important details on the correct, safe and efficient methods of installation for Microshare Smart FM Solutions.

We have delivered and installed thousands of sensors to clients all over the world across a wide range of range of applications, so please get in contact with us if you need any assistance. Our expert team are on hand and ready to support you.

Contact installation@microshare.io should you require any assistance

Note Using your Microshare solutions safely

  • Follow the stated battery requirements before installing any batteries.

  • Never force a connector into a port. If the connector and port don’t join with reasonable ease, they probably don’t match. Make sure that the connector matches the port and that you have positioned the connector correctly in relation to the port.

  • Protect Microshare sensors from direct sunlight, wherever possible.

  • Use Microshare solutions in environments according to their specification. Most products arefor indoor use only.

  • There are no user-serviceable parts inside Microshare sensors. For service personnel: Alwaysunplug external power supply, remove batteries, and turn off UPS battery before service operation.

  • Microshare sensors may be damaged by improper storage or handling. Take care not to drop them during transport and installation.

Banner

WARNING: Do not attempt to open or disassemble any Microshare solutions. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Microshare may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

SC01 – Activity Level Indicator (Motion Based)

The Activity Level Indicator solution from Microshare is a complete sensing service for facilities manager looking to gain better insights, improve security and develop new usage applications around their facilities.

What’s in the box? In terms of deploying quickly, the Activity Level Indicator solution from Microshare includes:

  • Long-life (up to two years) battery-operated wireless sensors, which can be easily and discreetly installed at key points around your facilities

  • device connectivity, access to data and alerts via Microshare Business Tools dashboards or direct API access to data through Microshare Smart Network.

Note: In order to reduce the possibility of recording false alerts, a simple cap is pre-fitted to the sensor unit to limit the sensing range of the device. This ensures that only activity within the required line of sight is measured.

Banner

Sensing range without cap

Installation instructions:

1. Activating the wireless sensor
- Our wireless sensors are pre-installed with batteries. To activate pull the shipping isolating battery tab from the sensor.
- After around a minute, the LED on the sensor should begin to flash intermittently.
Banner
2. Preparing the sensor for fixing

- If you are fixing the sensor using suitable adhesive tape, ensure that you place the tape on the opposite side of the QR code.
Banner
3. Registering the sensor using the Deploy-M app [iOS & Android]

- You should already have the Deploy-M app and login details as part of your project set-up with Microshare
- Login using your credentials, if you are unsure or require assistance, please contact installation@microshare.io
Banner
- Select the correct device cluster for the devices you are installing.
Note – a "Device Cluster" is simply grouping of sensors, usually in one space, that helps identify and annotate the data you receive from your Microshare solution.
Banner
 - Select the correct location where the device will be installed.
 
- Click Add  Banner
- Once the sensor has been added to the correct location on the app, click 'RESCAN' to open the devices camera Banner
- Scan the QR code located on the Sensor Banner
- Check that the Dev EUI [usually the second code on the sensor under the QR code] the shown matches the one on your device, then select save from the bottom of the screen. Banner
4. Fixing the sensor bracket

- Once you have completed the registration of the sensor on the Deploy-M app, you are ready to fix the sensor in place.
- This sensor is usually installed along the top of a door frame (on the inside of the room), with the sensing element pointed down and the QR code facing towards you. If there is no space at the top of the door frame, the device can also be installed on the top right or left of the doorframe, depending on which way the door opens - the main point to note is that the sensing element faces down and into the room being monitored.
- Using the adhesive on the sensor, attach the sensor with the QR code still visible and the sensor pointing downwards as shown.
Banner

Once you have completed your installation, or if you require any assistance, please contact installation@microshare.io


Did this doc help you?


For further questions or support, please contact us at support@microshare.io